{"_buckets": {"deposit": "dda2a536-0c1d-4ad3-b68c-a4a7dfbf46ba"}, "_deposit": {"created_by": 5, "id": "1457", "owners": [5], "pid": {"revision_id": 0, "type": "depid", "value": "1457"}, "status": "published"}, "_oai": {"id": "oai:iwatemed.repo.nii.ac.jp:00001457", "sets": ["130", "386"]}, "author_link": ["5175", "5187", "5178", "5179", "5171", "5183", "5188", "5174", "5181", "5177", "5182", "5180", "5185", "5173", "5184", "5186", "5176", "5172"], "item_2_biblio_info_14": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-04-25", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "65", "bibliographicPageStart": "57", "bibliographicVolumeNumber": "32", "bibliographic_titles": [{"bibliographic_title": "岩手医科大学歯学雑誌"}, {"bibliographic_title": "Dental journal of Iwate Medical University", "bibliographic_titleLang": "en"}]}]}, "item_2_creator_6": {"attribute_name": "著者名(日)", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "三上, 俊成"}], "nameIdentifiers": [{"nameIdentifier": "5171", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "齋藤, 亮"}], "nameIdentifiers": [{"nameIdentifier": "5172", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本, 弘紀"}], "nameIdentifiers": [{"nameIdentifier": "5173", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "両川, 明子"}], "nameIdentifiers": [{"nameIdentifier": "5174", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田中, 光郎"}], "nameIdentifiers": [{"nameIdentifier": "5175", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "武田, 泰典"}], "nameIdentifiers": [{"nameIdentifier": "5176", "nameIdentifierScheme": "WEKO"}]}]}, "item_2_creator_7": {"attribute_name": "著者名よみ", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "ミカミ, トシナリ"}], "nameIdentifiers": [{"nameIdentifier": "5177", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "サイトウ, マコト"}], "nameIdentifiers": [{"nameIdentifier": "5178", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "マツモト, ヒロキ"}], "nameIdentifiers": [{"nameIdentifier": "5179", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "リョウカワ, アキコ"}], "nameIdentifiers": [{"nameIdentifier": "5180", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "タナカ, ミツロウ"}], "nameIdentifiers": [{"nameIdentifier": "5181", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "タケダ, ヤスノリ"}], "nameIdentifiers": [{"nameIdentifier": "5182", "nameIdentifierScheme": "WEKO"}]}]}, "item_2_creator_8": {"attribute_name": "著者名(英)", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "MIKAMI, Toshinari", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "5183", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "SAITO, Makoto", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "5184", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "MATSUMOTO, Hiroki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "5185", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "RYOKAWA, Akiko", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "5186", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TANAKA, Mitsuro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "5187", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TAKEDA, Yasunori", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "5188", "nameIdentifierScheme": "WEKO"}]}]}, "item_2_description_1": {"attribute_name": "ページ属性", "attribute_value_mlt": [{"subitem_description": "P(論文)", "subitem_description_type": "Other"}]}, "item_2_description_11": {"attribute_name": "抄録(日)", "attribute_value_mlt": [{"subitem_description": "齲蝕の治療を行うにあたり,齲蝕部位の病理組織学的診断を行うことは実際に不可能である。そのため,実際に行われている臨床診断の精度は明らかでない。本研究の目的は,ふだん行われている診査方法による臨床診断の信頼性,および術者間における診断の変動についてin vitroで調べることである。臨床診断にはエアーシリンジを用いた視診,探針による触診,それにエックス線診が使われた。試験には抜去歯が用いられ,臨床診断とコンタクトマイクロラジオグラム(CMR)による最終診断が比較された。レーザー型齲蝕検出装置であるDIAGNOdent^\u003cTM\u003eも客観的に臨床診断を行う方法として検討を行った。その結果,臨床診断のうち81%がCMRによる最終診断と一致した。4名の歯科医師の特異度はC_1で0.8から1.0,C_2で0.63から0.88だった。敏感度はC_1で0.5から0.83,C_2で0.88から1.0だった。Kappa係数は0.45から0.66だった。DIAGNOdent^\u003cTM\u003eと最終診断の一致率は50%だった。結論として,術者間の再現性は必ずしも高くはなく,共通の診断方法を使った場合でも術者によって臨床診断は変化するように思われた。したがって,臨床診断と最終診断は81%が一致したが,より正確な臨床診断を行うためにはさらなる研究が必要と思われる。一方,単独のDIAGNOdent^\u003cTM\u003e計測値は現在のところ,臨床診断ほどには信頼できないものだった。", "subitem_description_type": "Other"}]}, "item_2_description_12": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "The histopathological diagnosis cannot be performed in the dental caries, and thus, accuracy of clinical diagnosis is uncertain. The purpose of this study is to examine the reliability of clinical diagnosis by conventional methods and to examine the diagnostic variation among examiners in vitro. Visual inspections using an air syringe, probing using a dental explorer and radiographic examinations were all used for clinical diagnosis. Clinical diagnosis and final diagnosis by the contact microradiography (CMR) were compared using extracted carious teeth. DIAGNOdent^\u003cTM\u003e, a laser fluorescence device for caries detection was also examined as an objective method for clinical diagnosis. As a result, 81% of the clinical diagnosis matched those from the CMR diagnosis. Specificity for clinical diagnosis of four dentists ranged between 0.8 and 1.0 (C_1) and between 0.63 and 0.88 (C_2). Sensitivity ranged between 0.5 and 0.83 (C_1) and between 0.88 and 1.0 (C_2). The Kappa values varied from 0.45 to 0.66. The results of DIAGNOdent^\u003cTM\u003e measurements correlated with the final diagnoses at the rate of 50%. In conclusion, inter-examiner reproducibility was not always high and clinical diagnosis seemed to vary by examiners even when common conventional methods were used. Thus, in order to provide a more accurate clinical diagnosis more investigation seems to be necessary, though 81% of clinical diagnosis matched final diagnosis. On the other hand, DIAGNOdent^\u003cTM\u003e measurement value alone was not as dependable as clinical diagnosis at present.", "subitem_description_type": "Other"}]}, "item_2_source_id_13": {"attribute_name": "雑誌書誌ID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00017474", "subitem_source_identifier_type": "NCID"}]}, "item_2_text_10": {"attribute_name": "著者所属(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "Department of Oral Pathology, School of Dentistry, Iwate Medical University"}, {"subitem_text_language": "en", "subitem_text_value": "Department of Pediatric Dentistry, School of Dentistry, Iwate Medical University"}, {"subitem_text_language": "en", "subitem_text_value": "Department of Pediatric Dentistry, School of Dentistry, Iwate Medical University"}, {"subitem_text_language": "en", "subitem_text_value": "Department of Pediatric Dentistry, School of Dentistry, Iwate Medical University"}, {"subitem_text_language": "en", "subitem_text_value": "Department of Pediatric Dentistry, School of Dentistry, Iwate Medical University"}, {"subitem_text_language": "en", "subitem_text_value": "Department of Oral Pathology, School of Dentistry, Iwate Medical University"}]}, "item_2_text_2": {"attribute_name": "記事種別(日)", "attribute_value_mlt": [{"subitem_text_value": "研究"}]}, "item_2_text_3": {"attribute_name": "記事種別(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "Original"}]}, "item_2_text_9": {"attribute_name": "著者所属(日)", "attribute_value_mlt": [{"subitem_text_value": "岩手医科大学歯学部口腔病理学講座"}, {"subitem_text_value": "岩手医科大学歯学部小児歯科学講座"}, {"subitem_text_value": "岩手医科大学歯学部小児歯科学講座"}, {"subitem_text_value": "岩手医科大学歯学部小児歯科学講座"}, {"subitem_text_value": "岩手医科大学歯学部小児歯科学講座"}, {"subitem_text_value": "岩手医科大学歯学部口腔病理学講座"}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2007-04-25"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "KJ00004579610.pdf", "filesize": [{"value": "938.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensefree": "Creative Commons : 表示 - 非営利 - 改変禁止", "licensetype": "license_free", "mimetype": "application/pdf", "size": 938100.0, "url": {"label": "KJ00004579610", "url": "https://iwatemed.repo.nii.ac.jp/record/1457/files/KJ00004579610.pdf"}, "version_id": "35df273a-6b4d-411f-a862-b8ff93fe9c20"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "歯科齲蝕", "subitem_subject_scheme": "Other"}, {"subitem_subject": "臨床診断", "subitem_subject_scheme": "Other"}, {"subitem_subject": "最終診断", "subitem_subject_scheme": "Other"}, {"subitem_subject": "コンタクトマイクロラジオグラフィー", "subitem_subject_scheme": "Other"}, {"subitem_subject": "DIAGNOdent^\u003cTM\u003e", "subitem_subject_scheme": "Other"}, {"subitem_subject": "dental caries", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "clinical diagnosis", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "final diagnosis", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "contact microradiography", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "DIAGNOdent^\u003cTM\u003e", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "齲蝕の臨床診断とDIAGNOdent^\u003cTM\u003e計測値の信頼性に関するコンタクトマイクロラジオグラムとの比較研究", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "齲蝕の臨床診断とDIAGNOdent^\u003cTM\u003e計測値の信頼性に関するコンタクトマイクロラジオグラムとの比較研究"}, {"subitem_title": "Reliability of clinical diagnosis and DIAGNOdent^\u003cTM\u003e measurement value for dental caries comparing with results of contact microradiographic examinations", "subitem_title_language": "en"}]}, "item_type_id": "2", "owner": "5", "path": ["130", "386"], "permalink_uri": "https://iwatemed.repo.nii.ac.jp/records/1457", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-04-25"}, "publish_date": "2007-04-25", "publish_status": "0", "recid": "1457", "relation": {}, "relation_version_is_last": true, "title": ["齲蝕の臨床診断とDIAGNOdent^\u003cTM\u003e計測値の信頼性に関するコンタクトマイクロラジオグラムとの比較研究"], "weko_shared_id": 5}
齲蝕の臨床診断とDIAGNOdent^<TM>計測値の信頼性に関するコンタクトマイクロラジオグラムとの比較研究
https://iwatemed.repo.nii.ac.jp/records/1457
https://iwatemed.repo.nii.ac.jp/records/145747a7cd8e-0ed0-4676-ac8a-23b8b3c49403
名前 / ファイル | ライセンス | アクション |
---|---|---|
KJ00004579610 (938.1 kB)
|
Creative Commons : 表示 - 非営利 - 改変禁止
|
Item type | 紀要論文(ELS) / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-04-25 | |||||
タイトル | ||||||
タイトル | 齲蝕の臨床診断とDIAGNOdent^<TM>計測値の信頼性に関するコンタクトマイクロラジオグラムとの比較研究 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Reliability of clinical diagnosis and DIAGNOdent^<TM> measurement value for dental caries comparing with results of contact microradiographic examinations | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
記事種別(日) | ||||||
研究 | ||||||
記事種別(英) | ||||||
en | ||||||
Original | ||||||
著者名(日) |
三上, 俊成
× 三上, 俊成× 齋藤, 亮× 松本, 弘紀× 両川, 明子× 田中, 光郎× 武田, 泰典 |
|||||
著者名よみ |
ミカミ, トシナリ
× ミカミ, トシナリ× サイトウ, マコト× マツモト, ヒロキ× リョウカワ, アキコ× タナカ, ミツロウ× タケダ, ヤスノリ |
|||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00017474 | |||||
書誌情報 |
岩手医科大学歯学雑誌 en : Dental journal of Iwate Medical University 巻 32, 号 1, p. 57-65, 発行日 2007-04-25 |