WEKO3
アイテム
{"_buckets": {"deposit": "de4e63ee-7851-4f31-a1e2-4dd49b09ee11"}, "_deposit": {"created_by": 12, "id": "3961", "owners": [12], "pid": {"revision_id": 0, "type": "depid", "value": "3961"}, "status": "published"}, "_oai": {"id": "oai:iwatemed.repo.nii.ac.jp:00003961", "sets": ["80", "123"]}, "author_link": ["12090", "12089", "12088"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-08", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "8", "bibliographicPageEnd": "914", "bibliographicPageStart": "909", "bibliographicVolumeNumber": "134", "bibliographic_titles": [{"bibliographic_title": "薬学雑誌"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "可視光応答型光触媒を用いた分解剤を作製し、その抗がん剤に対する分解能を検証した。その結果、今回作製した分解剤は、蛍光ランプ下においてもCPAを始めPTXやCPT-11、MTX、5-FUなど複数の抗がん剤を有意に分解することが確認された。光源を選ばず、あらゆる抗がん剤を分解する特性は、汚染の甚大なBSC内部のみならず、調整室や病室への応用も可能であると考えられ、医療現場における抗がん剤汚染を低減する有用なツールとなる可能性が示唆された。", "subitem_description_type": "Abstract"}]}, "item_10001_heading_23": {"attribute_name": "見出し", "attribute_value_mlt": [{"subitem_heading_banner_headline": "薬学部", "subitem_heading_headline": "臨床薬剤学", "subitem_heading_language": "ja"}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0031-6903", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "佐藤, 淳也"}], "nameIdentifiers": [{"nameIdentifier": "12088", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "菊地, 聡美"}], "nameIdentifiers": [{"nameIdentifier": "12089", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "工藤, 賢三"}], "nameIdentifiers": [{"nameIdentifier": "12090", "nameIdentifierScheme": "WEKO"}]}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Cyclophosphamide", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Cytarabine", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Fluorouracil", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Methotrexate", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Tungsten", "subitem_subject_scheme": "Other"}, {"subitem_subject": "*抗腫瘍剤", "subitem_subject_scheme": "Other"}, {"subitem_subject": "*光分解", "subitem_subject_scheme": "Other"}, {"subitem_subject": "酸化物", "subitem_subject_scheme": "Other"}, {"subitem_subject": "照明", "subitem_subject_scheme": "Other"}, {"subitem_subject": "*触媒作用", "subitem_subject_scheme": "Other"}, {"subitem_subject": "銅", "subitem_subject_scheme": "Other"}, {"subitem_subject": "*光", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Paclitaxel", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Irinotecan", "subitem_subject_scheme": "Other"}, {"subitem_subject": "蛍光灯", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Tungsten Oxide", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "医療環境中に汚染された抗がん剤を可視光応答型光触媒にて分解する試み", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "医療環境中に汚染された抗がん剤を可視光応答型光触媒にて分解する試み"}]}, "item_type_id": "10001", "owner": "12", "path": ["80", "123"], "permalink_uri": "https://iwatemed.repo.nii.ac.jp/records/3961", "pubdate": {"attribute_name": "公開日", "attribute_value": "2014-12-19"}, "publish_date": "2014-12-19", "publish_status": "0", "recid": "3961", "relation": {}, "relation_version_is_last": true, "title": ["医療環境中に汚染された抗がん剤を可視光応答型光触媒にて分解する試み"], "weko_shared_id": 12}
医療環境中に汚染された抗がん剤を可視光応答型光触媒にて分解する試み
https://iwatemed.repo.nii.ac.jp/records/3961
https://iwatemed.repo.nii.ac.jp/records/3961a6ccacbe-2159-495b-a0c1-ba868e2d0121
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-12-19 | |||||
タイトル | ||||||
タイトル | 医療環境中に汚染された抗がん剤を可視光応答型光触媒にて分解する試み | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
佐藤, 淳也
× 佐藤, 淳也× 菊地, 聡美× 工藤, 賢三 |
|||||
書誌情報 |
薬学雑誌 巻 134, 号 8, p. 909-914, 発行日 2014-08 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0031-6903 | |||||
見出し | ||||||
大見出し | 薬学部 | |||||
小見出し | 臨床薬剤学 | |||||
言語 | ja |