WEKO3
アイテム
{"_buckets": {"deposit": "cb85f01b-c09f-4acf-a33e-f82e7bdd2d9f"}, "_deposit": {"created_by": 12, "id": "4994", "owners": [12], "pid": {"revision_id": 0, "type": "depid", "value": "4994"}, "status": "published"}, "_oai": {"id": "oai:iwatemed.repo.nii.ac.jp:00004994", "sets": ["80", "577"]}, "author_link": ["18404", "18399", "18403", "18401", "18402", "18400", "18405", "18406"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-06", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "756", "bibliographicPageStart": "751", "bibliographicVolumeNumber": "134", "bibliographic_titles": [{"bibliographic_title": "薬学雑誌"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "抗がん剤調製環境における汚染調査において5-FUを対象としたクーポン法が、シクロホスファミド(CPA)に代わる抗がん剤被曝並びに汚染のモニタリングに有用であるか検討した。着衣表面にクーポンを貼付し、その汚染量を測定した。貼付期間は、3つの調査期間中において化学療法に係わる業務時間中の8時間とし、貼付部位としては、非調製薬剤師及び看護師は1例につき1枚のクーポンを白衣の腹部、調製を担当した薬剤師にはガウンの腕部と胸部にそれぞれ1枚のクーポンを貼付した。3つの調査期間中に使用した108枚のクーポン中78枚(72%)から5-FUを検出した。CPAについては8枚(7%)のみから検出した。調製者含む3例の薬剤師及び3例の看護師の着衣への汚染量では、CPAについては、いずれのクーポンからも検出されなかった。", "subitem_description_type": "Abstract"}]}, "item_10001_heading_23": {"attribute_name": "見出し", "attribute_value_mlt": [{"subitem_heading_banner_headline": "その他", "subitem_heading_headline": "その他", "subitem_heading_language": "ja"}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0031-6903", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "佐藤, 淳也"}], "nameIdentifiers": [{"nameIdentifier": "18399", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森, 恵"}], "nameIdentifiers": [{"nameIdentifier": "18400", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐々木, 拓弥"}], "nameIdentifiers": [{"nameIdentifier": "18401", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "二瓶, 哲"}], "nameIdentifiers": [{"nameIdentifier": "18402", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "熊谷, 真澄"}], "nameIdentifiers": [{"nameIdentifier": "18403", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中山, 誠也"}], "nameIdentifiers": [{"nameIdentifier": "18404", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高橋, 勝雄"}], "nameIdentifiers": [{"nameIdentifier": "18405", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "工藤, 賢三"}], "nameIdentifiers": [{"nameIdentifier": "18406", "nameIdentifierScheme": "WEKO"}]}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "*Cyclophosphamide", "subitem_subject_scheme": "Other"}, {"subitem_subject": "*Fluorouracil", "subitem_subject_scheme": "Other"}, {"subitem_subject": "*環境モニタリング", "subitem_subject_scheme": "Other"}, {"subitem_subject": "看護師", "subitem_subject_scheme": "Other"}, {"subitem_subject": "*職業性曝露", "subitem_subject_scheme": "Other"}, {"subitem_subject": "人工環境", "subitem_subject_scheme": "Other"}, {"subitem_subject": "*調剤", "subitem_subject_scheme": "Other"}, {"subitem_subject": "薬剤師", "subitem_subject_scheme": "Other"}, {"subitem_subject": "白衣", "subitem_subject_scheme": "Other"}, {"subitem_subject": "予防衣", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ヒト", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "抗がん剤調製環境における汚染調査 クーポン法による5-FUモニタリングの有用性", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "抗がん剤調製環境における汚染調査 クーポン法による5-FUモニタリングの有用性"}]}, "item_type_id": "10001", "owner": "12", "path": ["80", "577"], "permalink_uri": "https://iwatemed.repo.nii.ac.jp/records/4994", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-02-10"}, "publish_date": "2015-02-10", "publish_status": "0", "recid": "4994", "relation": {}, "relation_version_is_last": true, "title": ["抗がん剤調製環境における汚染調査 クーポン法による5-FUモニタリングの有用性"], "weko_shared_id": 12}
抗がん剤調製環境における汚染調査 クーポン法による5-FUモニタリングの有用性
https://iwatemed.repo.nii.ac.jp/records/4994
https://iwatemed.repo.nii.ac.jp/records/4994ae69a908-611c-4b1d-994f-a1ceb3796787
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-02-10 | |||||
タイトル | ||||||
タイトル | 抗がん剤調製環境における汚染調査 クーポン法による5-FUモニタリングの有用性 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
佐藤, 淳也
× 佐藤, 淳也× 森, 恵× 佐々木, 拓弥× 二瓶, 哲× 熊谷, 真澄× 中山, 誠也× 高橋, 勝雄× 工藤, 賢三 |
|||||
書誌情報 |
薬学雑誌 巻 134, 号 6, p. 751-756, 発行日 2014-06 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0031-6903 | |||||
見出し | ||||||
大見出し | その他 | |||||
小見出し | その他 | |||||
言語 | ja |